Construction precautions
The substrate temperature must be 3 ℃ above the dew point
When the ambient temperature is below 5 ℃, outdoor construction is not suitable as the curing reaction between epoxy and curing agent stops
Relative humidity not exceeding 85%
Used as a protective coating for marine fuel tanks, crude oil tanks, ballast water tanks, and main engine bases.
Color: Black
Construction parameters
Density approximately: 1.40g/cm3
Proportion: Component A: Component B=7:4 (weight ratio)
Dry film thickness: 125 μ m
Wet film thickness: 187 μ m
Theoretical coating amount: 4.5 m2/kg
Suggested number of coating layers: 1 layer for airless spraying, 2-3 layers for brush or roll coating, with a dry film thickness of 125 μ m
Previous matching paint: H54-82 (834) aluminum powder epoxy asphalt oil resistant primer